BUIC System History

The need for a backup system for the SAGE System Direction Centers became apparent even before SAGE was fully implemented. In June 1961 the Department of Defense issued a directive to establish such a system in two phases. The system came to be known as the BackUp Intercept Control (BUIC) system. The first phase, BUIC I, returned to the pre-SAGE system of decentralized manual intercept control for backup. The second phase, BUIC II, was to be the establishment of automated intercept control facilities that could partially assume the role of a SAGE direction center if it were disabled. Limitations of the second phase led to the establishment of a third phase, BUIC III, that was approved by DoD on 30 Nov 1964.

BUIC I

BUIC I created a system from the existing radar sites that grouped them into NORAD Control Center (NCC) sites, Ground Control Intercept (GCI) sites and surveillance sites. BUIC I was to have 27 manual NCCs that could each take command of the airspace in the event that a SAGE direction center was incapacitated and an adjacent SAGE direction center could not assume control. The GCI stations were equipped to run manual intercepts and the surveillance sites fed track data to the NCCs and to the GCI sites. The BUIC I System was in place by the end of 1962.

BUIC II

--TBF--

BUIC III

--TBF--

Deactivation

--TBF-- Sources:

  • Searle, Lloyd V.; Rosove, Perry E.; Sydow, Eugene H. , Systems Management Applied to Large Computer Programs in BUIC III; Review of Experience, USAF Air Force Systems Command, Jun 1969, Prepared under Contract No. F19628-67-C-0026 by System Development Corporation, Pdf

See Also:


BUIC II & III Sites (edit list)
Site Type State Unit ID BUIC II BUIC III Deactive GPS Notes
Calumet AFS MI 665th AD Gp Z-016 1965-00-00 1969-10-00 1974-01-01 47.37111,
-88.17056
Charleston AFS ME 765th AD Gp Z-065 1966-03-01 1969-12-00 1974-01-01 45.09167,
-69.095
Fortuna AFS ND 780th AD Gp Z-027 1966-03-01 1969-00-00 1974-01-01 48.90389,
-103.86667
Fallon AFS NV 858thAD Gp Z-156 1966-04-01 196?-00-00 1974-01-01 39.40528,
-118.72206
Havre AFS MT 778th AD Gp Z-025 1966-04-01 196?-00-00 1974-01-01 48.88083,
-109.945
Keno AFS OR 827th AD Gp Z-180 1966-03-01 196?-00-00 1977-00-00 42.06889,
-121.97222
Mount Laguna AFS CA 751st AD Gp Z-076 1966-04-01 196?-00-00 1974-01-01 32.87667,
-116.415
North Truro AFS MA 762nd AD Gp Z-010 1965-09-01 1968-00-00 1974-01-01 42.03149,
-70.05329
Port Austin AFS MI 754th Radar Sqdn Z-061 1965-00-00 1968-00-00 1970-01-15 44.03028,
-83.00167
Lost BUIC III Status 1970
Tyndall AFS FL 678th AD Gp Z-198 1966-04-01 1968-03-07 1983-03-01 30.0760296,
-85.61064
BUIC III Tng Site
Keesler AFB MS Tech Training 1965-00-00 1968-00-00 30.401932,
-88.923234
Maint Training
Bryan Hall
Blaine AFS WA 757th Radar Sqdn Z-046 1966-03-01 1969-00-00 48.91333,
-122.73444
Finland AFS MN 756th Radar Sqdn Z-069 1966-04-01 1969-00-00 47.45361,
-91.2375
Cape Charles AFS VA 771st Radar Sqdn Z-056 1966-03-01 37.13278,
-75.95306
Montauk AFS NY 773rd Radar Sqdn Z-045 1966-04-01 41.0675,
-71.90556
Palermo AFS NJ 770th Radar Sqdn Z-054 1965-00-00 39.22194,
-74.68722
Fort Fisher AFS NC 701st AD Gp Z-115 1969-00-00 1974-01-01 33.99,
-77.91833
Othello AFS WA 637th AD Gp Z-040 196?-00-00 1974-01-01 46.72139,
-119.18
Baudette AFS MN 692nd AD Gp Z-132 1968-00-00 1974-01-01 48.66992,
-94.62081
Saint Margarets RCAF NB 21 Radar Sqdn C-5 1969-01-01 1983-07-19 46.909167,
-65.209167
BUIC II Manual
BUIC III
Senneterre RCAF QC 34 Radar Sqdn C-8 1968-12-01 1973-00-00 48.36195,
-77.22271
BUIC II Manual
BUIC III